ND-70348 (E) CHAPTER 4
Page 404
Revision 3.0
ARTD
RT
FUNCTION
REMARKS
81
LPTM Sender Inter-Digit Pause Index
0= DP/1 sec., PB/0.5sec. 1= 600 msec.
2= 800 msec. 3= 1000 msec.
4= 1200 msec. 5= 1400 msec.
6= 1600 msec. 7= 1800 msec.
8= 2000 msec. 9= 2200 msec.
10= 2400 msec. 11= 2600 msec.
12= 2800 msec. 13= 3000 msec.
14= 3200 msec. 15= 3400 msec.
(In case of MFC)
0= 12.0 sec. 1= 5.5 sec.
2= 7.0 sec. 3= 8.5 sec.
4= 10.0 sec. 5= 11.5 sec.
6= 13.0 sec. 7= 14.5 sec.
8= 16.0 sec. 9= 17.5 sec.
10= 20.0 sec. 11= 22.0 sec.
12= 24.0 sec. 13= 26.0 sec.
14= 28.0 sec. 15= 30.0 sec.
Note:
Possible to
use when ad-
justing the
duration of
Pause in the
case of Speed
Calling Sys-
tem or Add-
ing digits.
82 RSAX 0000Always assign data “0”.
83 CST 0000Always assign data “0”.
84 CSEG 0000Always assign data “0”.
85 CSEU 0000Always assign data “0”.
86 CSEL 0000Always assign data “0”.
87 CMP 0000Always assign data “0”.
88 TALK 0000Always assign data “0”.
89 FOT 0000Always assign data “0”.
90 RST 0000Always assign data “0”.
91
TOCI Trunk Override Calling
0= Override Inhibited (Calling side).
1= Tie Line Override Service is provided (Calling side).
92
TOCD Trunk Override Called
0= Override Inhibited (Called side).
1= Tie Line Override Service is provided (Called side).
93 ODGD 0000Always assign data “0”.
94 RLS 0000Always assign data “0”.
95
GWD Gate Way Data Service
0= Out of Service 1= Gate Way System
2-15= Not used