ND-70348 (E) CHAPTER 4
Page 444
Revision 3.0
ALRNN
98 CI
ISDN transmitting information
0 = Out of Service
1 = 16-Digit Caller Number Service, Attribute Informa-
tion Notification Service, and Calling Sub-Address
Transfer Service
2-15= Not used
99 OID 0000Always assign data“0.”
100TKS 0000Always assign data“0.”
101 PAD2
Pad Control Data 2
0-7 = For Pad value, See the NEAX7400 ICS (IMX)
Circuit Card Manual.
PAD value can also be
set by switch setting on
the 8TLT (Long Line
Telephone = TELT) card.
102TRM 0000Always assign data “0.”
103 TRPX 0000Always assign data “0.”
104LDR 0000Always assign data “0.”
105TSC 0000Always assign data “0.”
106SATS 0000Always assign data “0.”
107RVPX 0000Always assign data “0.”
108DQ 0000Always assign data “0.”
109 SLOV
Slumber Time Override Service
0 = Out of Service 1 = In Service
0000
110 SDTO
System message automatic output when Connection Ac-
knowledge signal has not been received.
0 = Out of Service 1 = In Service
111 ADVPRA
ISDN PRI Failure Routing Service
0 = Out of Service 1 = In Service
This data is valid for
dummy routes.
112 IND
Inter-office Name Display
0 = Out of Service 1 = In Service
113UUI 0000Always assign data “0.”
114DCH 0000Always assign data “0.”
115 CMRT
Common use of Route Numbers of ISDN trunks
0 = Out of Service 1 = In Service
116 PREF 0000Always assign data “0.”
117DFS 0000Always assign data “0.”
118 BOB
Broad Band
0 = 64K 1 = N
× 64K
0000
119 HO1CH 0000Always assign data “0.”
120 IFR
Indonesia Compulsion Cut Service
0 = Out of Service 1 = In Service
0000Always assign data “0.”
LOGICAL ROUTE (LGRT) 1-899
REMARKSFUSION POINT CODE (FPC) 1-253
ROUTE NUMBER (RT) 1-255