ND-70348 (E) CHAPTER 4
Page 511-1
Revision 5.0
ARTIN
Note 1:
This data is available for the software Release 9 or later.
Note 2:
This data is valid for the software Release 11 or later.
CDN
LOGICAL ROUTE NUMBER (1-899)
TRUNK DATA
56 CLBK
Kind of Collect Call Blocking Signal (for Bra-
zil only)
0=GB-7
1=GB-3
57 UALAW
User Information for Layer 1 Protocol
Note 1
0 = Transparent
1 = µ-law output
2 = A-law output
3 = Not used
58 MCTFAC
MCT (MCID) Service Send Message
(for Australia only)
0 = When using MCT (MCID) service,
send INFORMATION message
1 = When using MCT (MCID) service,
send FACILITY message
Note 2
59 RE
Recall Supplementary Service
0/1 = Out of service/In service
Note 2
60 PR
Path Replacement Additional Network
Feature
0/1 = Out of service/In service
Note 2
61 COT
Continuity check for Signaling System
No.7
0/1 = Out of service/In service
Note 2
62 SS7
Signaling System No.7
0/1 = CCIT No.7/SS7
Note 2

Table of Contents