ND-70348 (E) CHAPTER 4
Page 657
Revision 3.0
ASYDN
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 –1535
DATA
(DATA)
00 – FF
(Hex)
BIT CORRE-
SPONDING DATA
SYSTEM DATA CONTENTS (MDATA)
DATA
0/1
BIT
1
5
b
0
Access Code for C.F.-Busy Line and C.F. - Don’t Answer
Services
0/1 = Same/Separate
Note: If “0” is assigned, assign either SID: 10 or
12 in the ASPA command.
b
1
Maximum number of Multiple Call Forwarding - All
Calls/Busy Line occurrences:
Note: This data is valid when SYS-1, INDEX 69, bit
7 is assigned as“1”
b
2
b
3
b
4
Miscellaneous Timer
Counter
(MTC)
(0-7)
Call Back - Delay Timer
Timer Value Setting is MTC
×2 sec.
When this data is “000” ,
Timer value is 2 sec.
b
5
b
6
b
7
Call Back - Delay Timer
0/1 = Ineffective/Effective
600 Not used
700 Not used
b
3
0
0
0
0
b
2
0
0
1
1
b
1
0
1
0
1
: once
:
: twice
: three times
b
3
1
1
1
1
b
2
0
0
1
1
b
1
0
1
0
1
: four times
:
: five times
: