EasyManuals Logo

NEC NEAX 7400 IMX User Manual

NEC NEAX 7400 IMX
857 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
ND-70348 (E) CHAPTER 4
Page 94
Revision 4.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
16
b
0
1-digit Station Number
0/1 = Out/In Service
b
1
2-digit Station Number
0/1 = Out/In Service
b
2
3-digit Station Number
0/1 = Out/In Service
b
3
4-digit Station Number
0/1 = Out/In Service
b
4
5-digit Station Number
0/1 = Out/In Service
b
5
6-digit Station Number
0/1 = Out/In Service (Hotel system only)
0
b
6
Not used
0
b
7
17
b
0
This bit (data “1”) allows single line stations to switch hook
flash and dial an access code while hearing RBT, to place a
voice call to a or activate the D
term
s Message Reminder Key.
0/1 = Out/In Service
b
1
This bit (data “1”) designates that EROW calls can be placed
via the Voice Button of a D
term
.
0/1 = Out/In Service
b
2
Privacy Release Service for D
term
0/1 = Out/In Service
b
3
This bit (data “1”) activates Privacy Release Warning Tone.
0/1 = Not Send/Send
b
4
Blind Transfer to Attendant 0/1 = Out/In Service
0
b
5
Not used
b
6
Line Privacy Expansion service
0/1 = Out/In Service
Note:
Effective when b
2
= 1
b
7
Bridge Call 0/1 = Privacy/Non-Privacy Operation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC NEAX 7400 IMX and is the answer not in the manual?

NEC NEAX 7400 IMX Specifications

General IconGeneral
BrandNEC
ModelNEAX 7400 IMX
CategoryServer
LanguageEnglish

Related product manuals