ND-70348 (E) CHAPTER 4
Page 94
Revision 4.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
16
b
0
1-digit Station Number
0/1 = Out/In Service
b
1
2-digit Station Number
0/1 = Out/In Service
b
2
3-digit Station Number
0/1 = Out/In Service
b
3
4-digit Station Number
0/1 = Out/In Service
b
4
5-digit Station Number
0/1 = Out/In Service
b
5
6-digit Station Number
0/1 = Out/In Service (Hotel system only)
0
b
6
Not used
0
b
7
17
b
0
This bit (data “1”) allows single line stations to switch hook
flash and dial an access code while hearing RBT, to place a
voice call to a or activate the D
term
s Message Reminder Key.
0/1 = Out/In Service
b
1
This bit (data “1”) designates that EROW calls can be placed
via the Voice Button of a D
term
.
0/1 = Out/In Service
b
2
Privacy Release Service for D
term
0/1 = Out/In Service
b
3
This bit (data “1”) activates Privacy Release Warning Tone.
0/1 = Not Send/Send
b
4
Blind Transfer to Attendant 0/1 = Out/In Service
0
b
5
Not used
b
6
Line Privacy Expansion service
0/1 = Out/In Service
Note:
Effective when b
2
= 1
b
7
Bridge Call 0/1 = Privacy/Non-Privacy Operation