EasyManuals Logo

Oracle FS1-2 User Manual

Oracle FS1-2
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
Replace a Controller Fan Module
If a fan module fails, the system issues critical alerts. Replace failed fan modules
as soon as possible.
Prerequisites:
Ensure that you have a Phillips Number 2 screwdriver with at least a 4-inch
shaft.
Before handling a component, touch a grounded surface to discharge any
static electricity.
Aach an electrostatic discharge (ESD) wrist strap to your wrist, and stand
on an ESD mat while replacing components.
Deploy any rack anti-tilt mechanism before releasing the release buons and
extending the Controller chassis.
Fail over the Controller before replacing the component using Guided
Maintenance.
Note: The Controller must be failed over to prevent data loss or data
corruption during the component replacement process.
Initiate Guided Maintenance only when you are able to replace the fan
module immediately.
Each Controller has v
e fan modules that are located side-by-side at the center
inside the Controller chassis. A fan module is a customer replaceable unit (CRU).
Replacing a fan module requires you to bring the Controller oine. The
following gure shows a Controller fan module.
Figure 64: Fan module
Controller Replacement Procedures
93

Table of Contents

Other manuals for Oracle FS1-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle FS1-2 and is the answer not in the manual?

Oracle FS1-2 Specifications

General IconGeneral
BrandOracle
ModelFS1-2
CategoryStorage
LanguageEnglish

Related product manuals