Remote Control Commands
R&S
®
SMW200A
1053User Manual 1175.6632.02 ─ 30
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:FREQuency <Frequency>
Sets or indicates the carrier frequency, depending on the selected carrier frequency
mode.
Parameters:
<Frequency> integer
Range: depends on the installed options
*RST: 0
E.g. -60 MHz to +60 MHz (R&S SMW-B10)
Example:
SOURce1:BB:ARBitrary:MCARrier:CARRier:MODE ARB
SOURce1:BB:ARBitrary:MCARrier:CARRier1:
FREQuency 5.0
Sets 5.0 MHz carrier frequency.
Manual operation: See "Carrier Freq [MHz]" on page 392
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:PHASe <Phase>
Sets the start phase of the selected carrier.
Parameters:
<Phase> float
Range: 0 to 359.99
Increment: 0.01
*RST: 0
Default unit: DEG
Example:
SOURce1:BB:ARBitrary:MCARrier:CARRier19:PHASe
90
Sets a start phase.
Manual operation: See "Phase" on page 392
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:POWer <Power>
Sets the gain of the selected carrier.
Parameters:
<Power> float
Range: -80 to 0
Increment: 0.01
*RST: 0
Default unit: dB
Example:
SOURce1:BB:ARBitrary:MCARrier:CARRier15:POWer
-50
Sets the power of carrier 15 to -50 dB.
Manual operation: See "Gain" on page 392