Remote Control Commands
R&S
®
SMW200A
1147User Manual 1175.6632.02 ─ 30
Parameters:
<Source> USER | DOUT
DOUT
Enabled for BBMM1|BBMM2 connectors
*RST: USER
Example:
:SOURce:IQ:OUTPut:DIGital:BBMM2:SRATe:SOURce
DOUT
Sample rate estimation based on the applied I/Q data clock
:SOURce:IQ:OUTPut:DIGital:BBMM2:SRATe?
Manual operation: See "Source" on page 177
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:SRATe <SRate>
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:SRATe <SRate>
Sets/queries the sample rate of the digital I/Q output signal.
Parameters:
<SRate> float
Range: 25E6 to max*
Increment: 100E6
*RST: 100E6
*) max value depends on the installed options as follows:
R&S SMW-B10: max = 200E6 and depends on connected
receiving device
R&S SMW-B9: max = 250E6
See also Chapter 4.3.4, "Supported Digital Interfaces Depending
on the System Configuration", on page 119.
Example: See [:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:SRATe:
SOURce on page 1146.
Manual operation: See "Value" on page 177
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:CDEVice?
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:CDEVice?
Queries information on the connected device.
Return values:
<CDevice> string
Example:
:SOURce:IQ:OUTPut:DIGital:BBMM2:CDEVice?
Usage: Query only
Manual operation: See "Connected Device" on page 177
SOURce Subsystem