EasyManua.ls Logo

Rohde & Schwarz R&S SMW200A - Page 636

Rohde & Schwarz R&S SMW200A
1403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Monitoring Signal Characteristics
R&S
®
SMW200A
636User Manual 1175.6632.02 ─ 30
This example is based on the predefined marker signals. The goal is to capture and
measure the short active frame parts to explain the measurement in principle. In your
particular case, you would rather measure some exact signal parts or even frame parts
and you may have to define one or more customized marker signals.
1. Press the PRESET key.
2. In the block diagram, select "Baseband A > IEEE 802.11" and perform the settings
shown on the following figure:
The baseband signal is a bursted signal with different and short duty cycles of
around 1%.
3. Select "IEEE 802.11 WLAN > Marker" and enable the two required marker signals.
The Figure 9-19 shows an example of a possible marker configuration for measur-
ing the baseband power of the second frame block.
Figure 9-19: Example: Marker configuration for multi-gated baseband power measurements.
Perform, for example, the following:
Querying Information on the Baseband Power Levels