Serial bus analysis
R&S
®
RTM3000
329User Manual 1335.9090.02 ─ 09
See also: "Status Word" on page 322
Remote command:
TRIGger:A:MILStd:STATus:BCReceived on page 686
TRIGger:A:MILStd:STATus:BUSY on page 686
TRIGger:A:MILStd:STATus:DBCaccept on page 687
TRIGger:A:MILStd:STATus:INSTrument on page 687
TRIGger:A:MILStd:STATus:MERRor on page 687
TRIGger:A:MILStd:STATus:SREQuest on page 687
TRIGger:A:MILStd:STATus:SUBSystem on page 687
TRIGger:A:MILStd:STATus:TERMinal on page 687
State ← Status
Toggles the logic state of the selected bit: 0 (low), 1 (high), or X (do not care).
Cmd. and data
Triggers on specified command and data.
Transmission ← Cmd. and data
Sets the transmission type: "BC-RT" (bus controller to remote terminal); "RT - BC"
(remote terminal to bus controller), "RT - RT" (remote terminal to remote terminal),"
Mode Code" with data.
Remote command:
TRIGger:A:MILStd:TTYPe on page 688
Data ← Cmd. and data
Triggers on a specified data.
Offset Compare ← Data ← Cmd. and data
Sets the condition how the decoded value is compared with the defined offset.
Remote command:
TRIGger:A:MILStd:DATA:OFFSet:CONDition on page 683
Offset ← Data ← Cmd. and data
Sets a word offset.
Remote command:
TRIGger:A:MILStd:DATA:OFFSet on page 683
Data Words ← Data ← Cmd. and data
Sets the number of words. Up to four words can be set.
Remote command:
TRIGger:A:MILStd:DATA:WORDs on page 683
Data Compare ← Data ← Cmd. and data
Sets the condition how the decoded value is compared with the defined range.
Remote command:
TRIGger:A:MILStd:DATA:CONDition on page 683
MIL-STD-1553 (option R&S