Signal generation (option R&S RTM-B6)
R&S
®
RTM3000
409User Manual 1335.9090.02 ─ 09
Remote command:
WGENerator:MODulation:FUNCtion on page 784
Frequency
Sets the frequency of the modulating waveform for AM/FM/ASK modulation.
Remote command:
WGENerator:MODulation:AM:FREQuency on page 785
WGENerator:MODulation:FM:FREQuency on page 785
WGENerator:MODulation:ASK:FREQuency on page 785
AM Depth
Sets the modulation depth, the percentage of the amplitude range that is used for AM
modulation.
Remote command:
WGENerator:MODulation:AM:DEPTh on page 785
Deviation
Sets the frequency deviation, the maximum difference between the FM modulated sig-
nal and the carrier signal.
Remote command:
WGENerator:MODulation:FM:DEViation on page 785
ASK Depth
Sets the modulation depth, the percentage of the amplitude range that is used for ASK
modulation.
Remote command:
WGENerator:MODulation:ASK:DEPTh on page 785
Polarity
Sets the polarity of the ramp function for AM and FM modulation.
Remote command:
WGENerator:MODulation:RAMP:POLarity on page 786
Hop. Frequency
Sets the second frequency of the FSK-modulated signal.
Remote command:
WGENerator:MODulation:FSK:HFREquency on page 786
FSK Rate
Sets the rate at which signal switches between the carrier frequency and the hopping
frequency.
Remote command:
WGENerator:MODulation:FSK:RATE on page 786