Remote control commands
R&S
®
RTM3000
697User Manual 1335.9090.02 ─ 09
Parameters:
<SearchCondition> WSTart | ERRor | STATus | DATA | COMMand | MCODe |
CDATa
*RST: WST
SEARch:PROTocol:MILStd:DATA:CONDition <Comparison>
For a data word, searches for a comparison condition.
Parameters:
<Comparison> OFF | EQUal | NEQual | GTHan | GEQual | LEQual | LTHan |
WITHin | OUTSide
*RST: OFF
SEARch:PROTocol:MILStd:DATA:MAXimum <DataMaximum>
For a data word, searches for a maximum value.
Parameters:
<DataMaximum> 01X-string
SEARch:PROTocol:MILStd:DATA:MINimum <DataMinimum>
For a data word, searches for a minimum value.
Parameters:
<DataMinimum> 01X-string
SEARch:PROTocol:MILStd:DATA:OFFSet <DataOffset>
For a data word, searches for a data offset.
Parameters:
<DataOffset> *RST: 0
SEARch:PROTocol:MILStd:DATA:WORDs <DataWords>
For a data word, searches for a number of words.
Parameters:
<DataWords> *RST: 1
SEARch:PROTocol:MILStd:ERRor <ErrorType>
Selects the error type to be searched for.
Parameters:
<ErrorType> SYNChronization | PARity | TIMeout | MANChester | ANY
Serial bus analysis

Table of Contents