Remote control commands
R&S
®
RTP
1402User Manual 1337.9952.02 ─ 12
LAYout:HISTogram:HORZ:RELative:STARt <HistogramName>,<RelativeStart>
LAYout:HISTogram:HORZ:RELative:STARt? <HistogramName>
Defines the horizontal start value of the histogram.
Parameters:
<RelativeStart> Range: 0 to 100
Increment: 0.1
*RST: 0
Default unit: %
Parameters for setting and query:
<HistogramName>
Usage: Asynchronous command
LAYout:HISTogram:HORZ:RELative:STOP
<HistogramName>,<RelativeStop>
LAYout:HISTogram:HORZ:RELative:STOP? <HistogramName>
Defines the horizontal stop value of the histogram.
Parameters:
<RelativeStop> Range: 0 to 100
Increment: 0.1
*RST: 100
Default unit: %
Parameters for setting and query:
<HistogramName>
Usage: Asynchronous command
LAYout:HISTogram:VERTical:MODE <HistogramName>,<Mode>
LAYout:HISTogram:VERTical:MODE? <HistogramName>
Defines or queries whether the value range limits are entered as absolute or relative
values.
Parameters:
<Mode> ABS | REL
*RST: ABS
Parameters for setting and query:
<HistogramName>
Usage: Asynchronous command
LAYout:HISTogram:VERTical:ABSolute:STARt <HistogramName>,<Start>
LAYout:HISTogram:VERTical:ABSolute:STARt? <HistogramName>
Defines the vertical start value of the histogram.
For numerical values, the input of a unit is not supported for this command.