Remote control commands
R&S
®
RTP
1429User Manual 1337.9952.02 ─ 12
EXECutable:PARameter on page 1546
EXECutable:WDIRectory on page 1547
Suffix:
<m>
.
1..10
See "Selection of the measurement group: MEASurement<m>"
on page 1359.
Parameters:
<RunExecutable> NOACtion | SUCCess | VIOLation
See Chapter 22.4.5, "Event parameter", on page 1147
*RST: NOACtion
Usage: Asynchronous command
22.12.14 Reference levels
General reference level settings......................................................................... 1429
Automatic configuration.......................................................................................1431
Manual configuration...........................................................................................1433
Hysteresis........................................................................................................... 1438
Tube....................................................................................................................1438
Results................................................................................................................ 1440
22.12.14.1 General reference level settings
REFLevel<m>:LDETection............................................................................................ 1429
REFLevel<m>:LMODe................................................................................................. 1430
REFLevel<m>:RELative:MODE.....................................................................................1430
REFLevel<m>:USRLevel.............................................................................................. 1431
REFLevel<m>:LDETection <Mode>
Defines whether the reference level is configured manually or automatically.
For automatic configuration, select the signal level to be used (see REFLevel<m>:
AUTO:MODE on page 1431).
Suffix:
<m>
.
Valid suffix numbers: 2 to 21, 61 to 68, 108 to 118, 151 to 157,
173 to 179
Source waveform of the measurement, see Chapter 22.4.1,
"Waveform suffix", on page 1141.
Parameters:
<Mode> AUTO | MANual
Example:
REFLevel2:LDETection MANual
Sets manual level configuration for Ch1Wfm1. C1W1 corre-
sponds to suffix number 2.
Automatic measurements