Remote control commands
R&S
®
RTP
1433User Manual 1337.9952.02 ─ 12
This function is only available in automatic reference level mode (see REFLevel<m>:
LDETection on page 1429).
Suffix:
<m>
.
Valid suffix numbers: 2 to 21, 61 to 68, 108 to 118, 151 to 157,
173 to 179
Source waveform of the measurement, see Chapter 22.4.1,
"Waveform suffix", on page 1141.
Parameters:
<Value> ON | OFF
Usage: Asynchronous command
REFLevel<m>:AUTO:COUNt <Value>
Defines the number of histograms from which the average is calculated.
Prerequisites:
REFLevel<m>:AUTO[:STATe] is set to ON
REFLevel<m>:LDETection on page 1429 is set to AUTO
Suffix:
<m>
.
Valid suffix numbers: 2 to 21, 61 to 68, 108 to 118, 151 to 157,
173 to 179
Source waveform of the measurement, see Chapter 22.4.1,
"Waveform suffix", on page 1141.
Parameters:
<Value>
Usage: Asynchronous command
22.12.14.3 Manual configuration
REFLevel<m>:ABSolute:HIGH...................................................................................... 1433
REFLevel<m>:ABSolute:LOW.......................................................................................1434
REFLevel<m>:ABSolute:TDIStance...............................................................................1434
REFLevel<m>:ABSolute:BDIStance...............................................................................1435
REFLevel<m>:ABSolute:MLEVel................................................................................... 1435
REFLevel<m>:ABSolute:ULEVel................................................................................... 1435
REFLevel<m>:ABSolute:LLEVel....................................................................................1436
REFLevel<m>:RELative:UPPer..................................................................................... 1436
REFLevel<m>:RELative:MIDDle....................................................................................1437
REFLevel<m>:RELative:LOWer.................................................................................... 1437
REFLevel<m>:ABSolute:HIGH <Value>
The signal value that represents a high level.