EasyManua.ls Logo

Rohde & Schwarz RTP044 - LIN (Option R&S RTP-K3)

Rohde & Schwarz RTP044
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTP
1657User Manual 1337.9952.02 ─ 12
22.17.7 LIN (option R&S RTP-K3)
Configuration.......................................................................................................1657
Trigger.................................................................................................................1659
Decode results.................................................................................................... 1665
LIN search settings............................................................................................. 1672
LIN search results............................................................................................... 1679
22.17.7.1 Configuration
BUS<m>:LIN:DATA:SOURce........................................................................................ 1657
BUS<m>:LIN:DATA:THReshold..................................................................................... 1657
BUS<m>:LIN:TECHnology............................................................................................1658
BUS<m>:LIN:BITRate.................................................................................................. 1658
BUS<m>:LIN:POLarity..................................................................................................1658
BUS<m>:LIN:STANdard............................................................................................... 1659
BUS<m>:LIN:DATA:SOURce <DataSource>
Sets the waveform of the data line.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<DataSource> C1W1 | C2W1 | C3W1 | C4W1 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 |
D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15
See Chapter 22.4.2, "Waveform parameter", on page 1145
*RST: C1W1
Usage: Asynchronous command
BUS<m>:LIN:DATA:THReshold <Threshold>
Sets a user-defined threshold value.
Alternatively, you can set the threshold according to the signal technology with
BUS<m>:LIN:TECHnology.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Threshold> Range: -12 to 12
Increment: 0.1
*RST: 0
Default unit: V
Protocols

Table of Contents

Other manuals for Rohde & Schwarz RTP044

Related product manuals