Remote control commands
R&S
®
RTP
2196User Manual 1337.9952.02 ─ 12
Usage: Query only
MTESt:RESult:VIOLation<m>[:SLICe]? <MaskTestName>
Suffix:
<m>
.
*
Violation index, corresponds to the number in the "Violation" col-
umn of mask test result.
Query parameters:
<MaskTestName>
Return values:
<Slice> Range: 0 to 4294967295
Increment: 1
*RST: 0
Usage: Query only
Asynchronous command
MTESt:RESult:VIOLation<m>:STARt? <MaskTestName>
MTESt:RESult:VIOLation<m>:STOP? <MaskTestName>
Return the start and stop time of the slice with the indicated violation.
Suffix:
<m>
.
*
Violation index, corresponds to the number in the "Violation" col-
umn of mask test result.
Query parameters:
<MaskTestName>
Return values:
<Time> Range: -100 to 100
Increment: 1E-3
*RST: 0
Default unit: s
Usage: Query only
Asynchronous command
22.18 Mixed signal option (MSO, R&S RTP-B1)
This chaptes decribes the remote commands of MSO option R&S RTP-B1.
Some of the commands in the following chapter are asynchronous. An overlapping or
asynchronous command does not automatically finish executing before the next com-
mand starts executing. If overlapping commands must be executed in a defined order,
e.g. to avoid wrong measurement results, they must be serviced sequentially.