Remote control commands
R&S
®
RTP
2302User Manual 1337.9952.02 ─ 12
DEEMbedding<m>:COMPonent<n>:SPONe <SParamFilePath>
DEEMbedding<m>:COMPonent<n>:SPTWo <SParamFilePath>
Set the file name, file format and path of the S-parameter file, and load the S-parame-
ters.
See also: "S-Parameters, Filetype" on page 1070.
Suffix:
<m>
.
1..4
Selects the channel that is configured for deembedding.
<n> 1..*
Selects the component. The DUT has suffix 1.
Parameters:
<SParamFilePath> String with path and file name with extension s2p (2-port com-
ponent) or s4p (4-port component).
Usage: Asynchronous command
22.23.4 Responses
DEEMbedding<m>:CADC?
Maximum attenuation or gain of the measurement setup before deembedding at DC.
This value is the expected basic attenuation or gain, which is corrected by deembed-
ding.
Suffix:
<m>
.
1..4
Selects the channel that is configured for deembedding.
Return values:
ValueAtDC Range: -1E+9 to 1E+9
Increment: 0.01
*RST: 0
Default unit: dB
Usage: Query only
DEEMbedding<m>:MATTenuation?
Maximum attenuation of the measurement setup before deembedding, with reference
to a frequency response normalized at DC to 0 dB. The deembedding filter must
amplify the amplitude response by the "Att
max
" value, and thus also increases the noise
by this value. The value also helps to decide whether deembedding is useful for the
defined effective bandwidth.
Suffix:
<m>
.
1..4
Selects the channel that is configured for deembedding.
Deembedding (Option R&S RTP-K121/-K122)