Remote control commands
R&S
®
RTP
1476User Manual 1337.9952.02 ─ 12
Usage: Query only
Asynchronous command
22.14.6 Eye mask testing
22.14.6.1 Definition of eye masks
To perform mask testing on eye diagrams, the option R&S RTP-K12 adds a special
mask definition type to the common mask definitions: the definition type "Eye".
MTESt:CEMask........................................................................................................... 1476
MTESt:EYEMask:TYPE................................................................................................1476
MTESt:EYEMask:HEIGht<m>[:VALue]........................................................................... 1477
MTESt:EYEMask:WIDTh<m>[:VALue]............................................................................1477
MTESt:EYEMask:MSKRight..........................................................................................1477
MTESt:EYEMask:MSKLeft............................................................................................1477
MTESt:EYEMask:HPERiod...........................................................................................1478
MTESt:EYEMask:MSKTop............................................................................................ 1478
MTESt:EYEMask:MSKBottom.......................................................................................1478
MTESt:EYEMask:TOFFset............................................................................................1478
MTESt:EYEMask:BOFFset........................................................................................... 1478
MTESt:EYEMask:TBSYmmetric.................................................................................... 1479
MTESt:EYEMask:TBWidth............................................................................................1479
MTESt:EYEMask:HPOSition......................................................................................... 1479
MTESt:EYEMask:VPOSition......................................................................................... 1479
MTESt:CEMask <MaskTestName>
Converts the test and mask definitions of the current mask test to a new mask test of
type "User".
Setting parameters:
<MaskTestName> String with the name of the mask test
Usage: Setting only
Asynchronous command
MTESt:EYEMask:TYPE <MaskTestName>,<Type>
MTESt:EYEMask:TYPE? <MaskTestName>
Defines the outline of the eye mask.
Parameters:
<Type> SQUare | DIAMond | HEXagon | OCTagon
*RST: DIAMond
Parameters for setting and query:
<MaskTestName> String with the name of the mask test