BUS<m>:LIN:STANdard <Standard>
Selects the version of the LIN standard.
See also: "LIN standard" on page 584
Suffix: 
<m>
.
1..4
Selects the serial bus.
Parameters:
<Standard> V1X | V2X | J2602 | AUTO
*RST:  AUTO
22.17.7.2
 Trigger
The trigger suffix <m> is always 1 and can be omitted. It selects the trigger event: Only
the A-trigger is available for triggering on serial buses.
To trigger on a serial bus, make sure that:
●
TRIGger<m>:SOURce[:SELect] is set to SBUS.
●
The sources of the serial bus are channel signals: use BUS<m>:...:SOURce
commands.
●
Decoding is enabled: BUS<m>[:STATe] is set to ON.
TRIGger<m>:LIN:TYPE................................................................................................1659
TRIGger<m>:LIN:ICONdition.........................................................................................1660
TRIGger<m>:LIN:IMIN..................................................................................................1661
TRIGger<m>:LIN:IMAX.................................................................................................1661
TRIGger<m>:LIN:DCONdition....................................................................................... 1661
TRIGger<m>:LIN:DMIN................................................................................................ 1661
TRIGger<m>:LIN:DMAX............................................................................................... 1661
TRIGger<m>:LIN:BORDer............................................................................................ 1662
TRIGger<m>:LIN:DLECondition.....................................................................................1662
TRIGger<m>:LIN:DLENgth........................................................................................... 1662
TRIGger<m>:LIN:IDOR<n>:ENABle...............................................................................1663
TRIGger<m>:LIN:IDOR<n>[:VALue]...............................................................................1663
TRIGger<m>:LIN:SYERror............................................................................................1663
TRIGger<m>:LIN:IPERror.............................................................................................1663
TRIGger<m>:LIN:CHKSerror.........................................................................................1664
TRIGger<m>:LIN:ERRPattern....................................................................................... 1664
TRIGger<m>:LIN:CRCDatalen...................................................................................... 1664
TRIGger<m>:LIN:STANdard..........................................................................................1665
TRIGger<m>:LIN:TYPE <Type>
Selects the trigger type for LIN analysis.
See: "Trigger type" on page 588.
Parameters:
<Type> SYNC | ID | IDOR | IDDT | WKFR | ERRC
Protocols