Remote control commands
R&S
®
RTP
1679User Manual 1337.9952.02 ─ 12
Parameters:
<ChecksumError> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:ERRPattern <SearchName>,<ErrorPattern>
SEARch:TRIGger:LIN:ERRPattern? <SearchName>
Sets the frame identifier to search for a checksum error.
Parameters:
<ErrorPattern> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148.
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:CRCDatalen <SearchName>,<CRCDataLength>
SEARch:TRIGger:LIN:CRCDatalen? <SearchName>
Sets the number of data bytes search for CRC errors.
Parameters:
<CRCDataLength> Range: 0 to 8
Increment: 1
*RST: 0
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:STANdard <SearchName>,<LINStandard>
SEARch:TRIGger:LIN:STANdard? <SearchName>
Sets the LIN standard to search for CRC errors.
Parameters:
<LINStandard> V1X | V2X | J2602 | AUTO
*RST: AUTO
Parameters for setting and query:
<SearchName>
22.17.7.5 LIN search results
The search on decoded LIN data returns the same results as the queries for decode
results.
In search result commands, you have to specify the <SearchName> parameter. It is a
string parameter that contains the search definition name.