Remote control commands
R&S
®
RTP
1597User Manual 1337.9952.02 ─ 12
<n> *
Selects the frame.
<o> *
Selects the word number.
Return values:
<Stop> Range: -100E+24 to 100E+24
*RST: 0
Default unit: s
Usage: Query only
BUS<m>:SPI:FRAMe<n>:WORD<o>:MISO?
Returns the data value of the specified word on the MISO line.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
<o> *
Selects the word number.
Return values:
<MISOValue> To set the value format, use FORMat:BPATtern.
The values below range, increment and reset are decimal
values.
Range: 0 to 4294967295
*RST: 0
Usage: Query only
BUS<m>:SPI:FRAMe<n>:WORD<o>:FMISo?
Returns the formatted value of the specified word on the MISO line.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
<o> *
Selects the word number.
Return values:
<FormattedMISOVal>
Usage: Query only