Remote control commands
R&S
®
RTP
1769User Manual 1337.9952.02 ─ 12
SEARch:TRIGger:HBTO:DADDress:MIN <SearchName>,<DestAddrPattMin>
SEARch:TRIGger:HBTO:DADDress:MIN? <SearchName>
Specifies the destination address bit pattern, or sets the start value of a pattern range.
Parameters:
<DestAddrPattMin> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:HBTO:DADDress:MAX
<SearchName>,<DestAddrPattMax>
SEARch:TRIGger:HBTO:DADDress:MAX? <SearchName>
Sets the end value of the destination address range if SEARch:TRIGger:HBTO:
DADDress:CONDition is set to INRange or OORange.
Parameters:
<DestAddrPattMax> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:HBTO:SADDress:CONDition <SearchName>,<SrcAddrOperator>
SEARch:TRIGger:HBTO:SADDress:CONDition? <SearchName>
Sets the condition for the source address. You can define an exact value or a value
range.
Parameters:
<SrcAddrOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one data pattern
to be set with the corresponding SEARch:TRIGger:HBTO:
SADDress:MIN command.
INRange | OORange
In range/Out of range: set the minimum and maximum value of
the range with SEARch:TRIGger:HBTO:SADDress:MIN and
SEARch:TRIGger:HBTO:SADDress:MAX.
*RST:
EQUal
Parameters for setting and query:
<SearchName>
Protocols