Remote control commands
R&S
®
RTP
1973User Manual 1337.9952.02 ─ 12
Query parameters:
<SearchName>
Return values:
<State> OK | LENGth | UNKNown | INComplete | CRC | PARity
OK
The frame was decoded normally and conforms to the frame
description.
LENGth
The length error indicates that the frame ended prematurely, or
an array in the frame had too few elements. The amount of bits
that the software expected (based upon the user's frame
description) was not found before the frame was terminated.
This might occur because a new frame synchronized, or a gap
appeared between the bits.
UNKNown
Unknown error
INComplete
The frame ended prematurely because it extends past the end
of the record.
CRC
Checksum error in cyclic redundancy check (error in data)
*RST:
OK
Usage: Query only
SEARch:RESult:CMSB<m>:FRAMe<n>:STOP? <SearchName>
Returns the stop time of the frame within the search result.
Suffix:
<m>
.
*
<n> *
Query parameters:
<SearchName>
Return values:
<Stop> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
SEARch:RESult:CMSB<m>:FRAMe<n>:TYPE? <SearchName>
Returns the name of the selected frame (n) from the user defined frame format
description, labeled according to BUS<m>:CMSB:FRAMe<n>:TYPE on page 1942.