EasyManua.ls Logo

Rohde & Schwarz RTP044 - Page 2104

Rohde & Schwarz RTP044
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTP
2104User Manual 1337.9952.02 ─ 12
Query parameters:
<SearchName>
Return values:
<Info>
Usage: Query only
SEARch:RESult:USBPd:FRAMe<m>:STARt? <SearchName>
Returns the start time of the frame with the selected frame number within the search
result.
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<Start> Range: -100E+24 to 100E+24
Increment: 100E-12
Default unit: s
Usage: Query only
SEARch:RESult:USBPd:FRAMe<m>:STATe? <SearchName>
Returns the status of the frame with the selected frame number within the search
result.
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<State> OK | UNKNown | INComplete | PREamble | SOP | CRC |
LENGth | FBFB
SOP
Start of packet warning
CRC
Cyclic redundancy check error
FBFB
4b5b error
*RST: OK