EasyManua.ls Logo

Rohde & Schwarz RTP044 - Page 668

Rohde & Schwarz RTP044
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protocol analysis
R&S
®
RTP
668User Manual 1337.9952.02 ─ 12
Frame check
Sets the specified frame check to be triggered on. The frame check setup consists of
the condition and one or two data patterns.
This field contains a value that is used to check the integrity of the various bits in the
frame fields (excluding the preamble / SFD).
"Condition"
Defines the operator to set a specific frame check, e.g. "Equal" or
"Not Equal") or a range.
"Data Min/Data"
Defines the bit pattern of the frame check pattern.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor", on page 519.
"Data Max"
The second data pattern is required to specify a range with conditions
"In range" and "Out of range".
Remote command:
TRIGger<m>:TBTO:CRC:CONDition on page 1791
TRIGger<m>:TBTO:CRC:MIN on page 1792
TRIGger<m>:TBTO:CRC:MAX on page 1791
Data
Sets the specified data to be triggered on. The data setup consists of the condition and
one or two data patterns.
"Condition"
Defines the operator to set a specific data, e.g. "Equal" or "Not
Equal") or a range.
"Data Min/Data"
Defines the bit pattern of the data pattern.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor", on page 519.
"Data Max"
The second data pattern is required to specify a range with conditions
"In range" and "Out of range".
Remote command:
TRIGger<m>:TBTO:DATA:DCONdition on page 1793
TRIGger<m>:TBTO:DATA:DMIN on page 1793
TRIGger<m>:TBTO:DATA:DMAX on page 1793
Index
Sets the specified value or range within this series of data that is considered for the
analysis. The index setup consists of the condition and one or two index values.
"Condition"
Defines the operator to set a specific index, e.g. "Equal" or a range.
"Index Min/Index"
Defines the bit pattern of the index pattern.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor", on page 519.
Ethernet 1000BASE-T1 (option R&S RTP-K58)

Table of Contents