Protocol analysis
R&S
®
RTP
737User Manual 1337.9952.02 ─ 12
"READ-MFG-INFO"
Retrieves manufacturing ID and vendor-specific information
"READ-VEND-INFO"
Retrieves the additional four delimited bytes containing vendor-spe-
cific information
"WRITE-ATTRIBUTE"
Sets the configuration parameters required for lane operation
"PWM-G0/PWM-G1/PWM-G2/PWM-G3/PWM-G4/PWM-G5/PWM-G6/PWM-G7"
Switches the transmission mode to the selected low-power gear
"HS-G1A/HS-G2A/HS-G3A/HS-G4A/HS-G1B/HS-G2B/HS-G3B/HS-G4B"
Switches the transmission mode to the selected high-speed gear
"Reserved"
Reserved bit command. These bits are reserved for future use.
Remote command:
SEARch:TRIGger:MPHY:LCCType on page 1901
WORD 1/WORD 2/WORD 3/WORD 4
Sets the specified words to be searched for. The setup for a word consists of the condi-
tion and one or two word patterns.
"Condition"
Defines the operator to set a specific word, e.g. "Equal" or " Not
Equal" or a range.
"Data Min/Data"
Defines the bit pattern of the word pattern.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor", on page 519.
"Data Max"
The second word pattern is required to specify a range with condi-
tions "In range" and "Out of range".
Remote command:
For " WORD 1":
SEARch:TRIGger:MPHY:LWONe:CONDition on page 1902
SEARch:TRIGger:MPHY:LWONe:MIN on page 1902
SEARch:TRIGger:MPHY:LWONe:MAX on page 1902
For " WORD 2":
SEARch:TRIGger:MPHY:LWTWo:CONDition on page 1903
SEARch:TRIGger:MPHY:LWTWo:MIN on page 1903
SEARch:TRIGger:MPHY:LWTWo:MAX on page 1903
For " WORD 3":
SEARch:TRIGger:MPHY:LWTHree:CONDition on page 1904
SEARch:TRIGger:MPHY:LWTHree:MIN on page 1904
SEARch:TRIGger:MPHY:LWTHree:MAX on page 1904
For " WORD 4":
SEARch:TRIGger:MPHY:LWFour:CONDition on page 1905
SEARch:TRIGger:MPHY:LWFour:MIN on page 1905
SEARch:TRIGger:MPHY:LWFour:MAX on page 1905