Protocol analysis
R&S
®
RTP
913User Manual 1337.9952.02 ─ 12
"Min"
Specifies the value or sets the start value of a range.
"Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command:
SEARch:TRIGger:DDR:DMAX on page 2177
SEARch:TRIGger:DDR:FRAMe<m>:FLD<n>:DMAX on page 2177
SEARch:TRIGger:DDR:DMIN on page 2177
SEARch:TRIGger:DDR:FRAMe<m>:FLD<n>:DMIN on page 2177
SEARch:TRIGger:DDR:DOPerator on page 2178
SEARch:TRIGger:DDR:FRAMe<m>:FLD<n>:DOPerator on page 2178
Index ← Set details
The search index setup consists of a comparison condition and one or two address
patterns.
"Condition"
Sets the comparison condition to a specific value or a range.
"Min"
Specifies the value or sets the start value of a range.
"Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command:
SEARch:TRIGger:DDR:IMAX on page 2179
SEARch:TRIGger:DDR:FRAMe<m>:FLD<n>:IMAX on page 2179
SEARch:TRIGger:DDR:IMIN on page 2179
SEARch:TRIGger:DDR:FRAMe<m>:FLD<n>:IMIN on page 2179
SEARch:TRIGger:DDR:IOPerator on page 2180
SEARch:TRIGger:DDR:FRAMe<m>:FLD<n>:IOPerator on page 2180
13.23.2.2 DDR search results
To get search results, "Enable" the search. You can minimize, shift or close the search
dialog.
The search results are listed in the search result table and marked in the waveform by
blue lines.
For an introduction to search results, see:
●
Chapter 11.1.2, "Search results", on page 449
●
Chapter 11.4.2, "Display zoom settings", on page 468
The results of the search are the same as for decoding, see Chapter 13.23.3, "DDR
decode results", on page 914.
Remote commands:
●
SEARch:RESult:DDR:FCOunt? on page 2180
●
SEARch:RESult:DDR:FRAMe<m>:FLD<n>:FVAL? on page 2181
●
SEARch:RESult:DDR:FRAMe<m>:FLD<n>:STARt? on page 2181
●
SEARch:RESult:DDR:FRAMe<m>:FLD<n>:STATus? on page 2181
●
SEARch:RESult:DDR:FRAMe<m>:FLD<n>:STOP? on page 2182
DDR (option R&S