Waveform generator (Option R&S RTP-B6)
R&S
®
RTP
966User Manual 1337.9952.02 ─ 12
Modulation signal
Selects the type of the modulation signal for the FM modulation types.
Remote command:
WGENerator<m>:MODulation:FM[:FUNCtion] on page 2226
Modulation freq
Sets the frequency of the modulation waveform.
Remote command:
WGENerator<m>:MODulation:FM:FREQuency on page 2226
Symmetry
Sets the symmetry for the ramp modulation waveform, the percentage of time that the
waveform is rising.
Remote command:
WGENerator<m>:MODulation:FM:SYMMetry on page 2226
Freq deviation
Sets the frequency deviation, the maximum difference between and FM modulated sig-
nal and the carrier signal.
Remote command:
WGENerator<m>:MODulation:FM:DEViation on page 2225