Command Reference RMON Commands
Usage guidelines
N/A.
Examples
The example below displays the RMON alarm table.
Ruijie#show rmon alarm
rmon alarm table:
index: 1
interval: 60
oid = 1.3.6.1.2.1.2.2.1.12.6
sampleType: 2
alarmValue: 0
startupAlarm: 3
risingThreshold: 20
fallingThreshold: 10
risingEventIndex: 1
fallingEventIndex: 1
owner: UserA
status: 1
Related
commands
Command
Description
rmon alarm number variable
interval {absolute | delta }
rising-threshold value
[event-number] falling-threshold value
[event-number] [owner
ownername]
Adds an alarm entry.
2.7 show rmon event
Use this command to display the event configuration.
show rmon event
Default
N/A.
Command mode
Privileged EXEC mode.
Usage guidelines
N/A.
Examples
The example below displays the event configuration.
Ruijie#show rmon event
rmon event table:
index = 1
description = ifInNUcastPkts is abnormal
type = 4

Table of Contents