Command Reference Supervisor Module Redundancy Commands
If this command is executed on the active supervisor module, the module will be reset and the
standby supervisor module will act as an active supervisor module.
The following conditions are required to perform hot backup switchover:
 This command is executed on the active supervisor module. There is a standby supervisor
module.
 Hot backups on all virtual switch devices (VSDs) are in real-time status.
 Hot backup switchovers on VSDs are not prevented temporarily by any service entity.
When there are multiple VSDs, the system judges whether the hot backup on each VSD allows
active/standby switchover; If any VSD does not allow the switchover, the command fails. Otherwise,
active/standby switchovers are enforced on all VSDs.
The following example performs active/standby supervisor module switchover.
Ruijie# redundancy forceswitch
This operation will reload the master unit and force switchover to the slave
unit. Are you sure to continue? [N/y] y
Resets the active supervisor module.
Use this command to reset the supervisor module.
redundancy reload { peer | shelf [ switchid ] }
Resets the standby supervisor module.
Resets both the active and standby supervisor modules on the device
which works as a single physical device. The device ID should be
specified on the device which works as a Virtual Switching Unit (VSU)
device.
VSU device ID, supported on a VSU device.
This parameter is not supported in stand-alone mode. It must be
contained in the redundancy reload shelf command in VSU
mode.