Command Reference CA-MONITOR Commands
Usage Guide
Use the command to display the current temperature and threshold configuration of each board.
The temperature threshold of CA products involves the alarm threshold and the hazard threshold.
Alarm threshold: When the temperature of the board exceeds the alarm threshold, the active supervisor
module generates a Syslog message and the Alarm LED on the panel becomes yellow.
Hazard threshold: It indicates the power-off temperature. When the temperature of the board exceeds
the hazard threshold, the board powers off automatically. In addition, the active supervisor module
generates a Syslog message and the Alarm LED on the panel becomes red.
Configuration
Examples
The following example displays the temperature and threshold configuration of all boards of S29XS.
Ruijie#show temperature
Slot Card_type Current(C) Status
------- -------------------------------- ---------- ---------
1/0 S2910-48GT4XS-E 43 ok
S2910-48GT4XS-E 42 ok
Ruijie#
The following example displays the temperature and threshold configuration of all boards of S29XS
PoE.
Ruijie#show temperature
slot_type Current(C) Status
------- -------------------------------- ---------- ---------
0 S2910C-24GT2XS-HP-E 28 ok
Ruijie#