Use the command to display the current temperature and threshold configuration of each board.
The temperature threshold of CA products involves the alarm threshold and the hazard threshold.
Alarm threshold: When the temperature of the board exceeds the alarm threshold, the active supervisor
module generates a Syslog message and the Alarm LED on the panel becomes yellow.
Hazard threshold: It indicates the power-off temperature. When the temperature of the board exceeds
the hazard threshold, the board powers off automatically. In addition, the active supervisor module
generates a Syslog message and the Alarm LED on the panel becomes red.
The following example displays the temperature and threshold configuration of all boards of S29XS.
Ruijie#show temperature
Slot Card_type Current(C) Status
------- -------------------------------- ---------- ---------
1/0 S2910-48GT4XS-E 43 ok
S2910-48GT4XS-E 42 ok
Ruijie#
The following example displays the temperature and threshold configuration of all boards of S29XS
PoE.
Ruijie#show temperature
slot_type Current(C) Status
------- -------------------------------- ---------- ---------
0 S2910C-24GT2XS-HP-E 28 ok
Ruijie#