K5: Mode groups, channels, axis interchange
5.4 Axis/spindle replacement
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
339
Current state and interpolation right of the axis
With which axis type and interpolation right a possible axis replacement is to be performed,
can be deducted from the system variable $AA_AXCHANGE_TYP[axis].
0: The axis is assigned to the NC program
1: Axis assigned to PLC or active as command axis or oscillating axis
2: Another channel has the interpolation right.
3: Axis is neutral axis.
4: Neutral axis is controlled by the PLC.
5: Another channel has the interpolation right, axis is requested for NC program.
6: Another channel has the interpolation right, axis is requested as neutral axis.
7: Axis active for PLC or as command or oscillating axis, axis is
requested for PLC program.
8: Axis active for PLC or as command or oscillating axis, axis is
requested as neutral axis.
9: Permanently assigned PLC axis, in state of neutral axis.
10: Permanently assigned PLC axis, controlled by PLC, in state of neutral axis.
Permanently assigned PLC axis
in state of neutral axis $AA_AXCHANGE_TYP = 9 and
controlled by PLC, in state of neutral axis $AA_AXCHANGE_TYP = 10
will be assigned to PLC independently of GET and RELEASE permanently.
Whether the axis can also be replaced is displayed via the system variable
$AA_AXCHANGE_STAT[axis].

Table of Contents

Other manuals for Siemens SINUMERIK Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK Series and is the answer not in the manual?

Siemens SINUMERIK Series Specifications

General IconGeneral
Axes ControlUp to 31 axes
CategoryControl Unit
ManufacturerSiemens
SeriesSINUMERIK
Control TypeCNC
Communication InterfacesEthernet, USB
Operating Temperature0°C to 45°C
Protection ClassIP20
Power Supply24V DC
DisplayColor TFT LCD

Related product manuals