OPERATION 5
MHL360 E 5.87
5.21.8 Hydraulic fluid temperature
Temp. (°C)
Actions
Less than
15
Start of the bottom warning level
Background (227/36): blue
h During operation, the back-
ground must be black. First
warm up the machine to operat-
ing temperature.
15 - 80
The lower warning level is reset
Background (227/36): black
h Working speed enabled again
From 80
Start of the top warning levels
Background (227/36): orange
Indicator (227/12)
Reduced working speed (FINE
MODE)
From 95
Background (227/36): red
Indicator (227/22) and message
(227/34): "WORK HYDRAULICS"
"DISABLED"
Disable the travel and work func-
tions
Less than
95
The upper warning levels are reset
Travel and work functions enabled
again
Less than
80
Visual warnings cancelled again
Working speed enabled again
Measures to be taken when a warning oc-
curs
Stop work immediately and allow the diesel
engine to continue running at its upper idle
speed.
If the engine fails to cool down, switch off
the diesel engine as quickly as possible.
Check the hydraulic oil cooler for contami-
nation. Clean if necessary.
If the warning message persists, call for
service personnel.
F
09 :43 11 .03. 2 011
MH LX X X / XXX X
18 00 U PM
0 5 1 0 15 20 2 5
95°C 7 5°C
0 ½ 1
9 %
120 0
36
34
33
12
22
BSB50646
Fig. 227 Monitoring the hydraulic oil temperature
12 Indicator for hydraulic oil temperature
22 Travel and work functions disabled indicator
33 Note text message indicator
34 Text message for the indicators
36 Indicator for the hydraulic oil temperature in °C and
warning levels based on background color

Table of Contents