EasyManua.ls Logo

Terex MHL360 E - Diesel Particle Filter Soot Loading

Terex MHL360 E
320 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 OPERATION
5.90 MHL360 E
5.21.11 Diesel particle filter soot loading
Loading
Actions
100 %
Prerequisite: Coolant tempera-
ture must be above 75°C at least
once after the diesel engine is
started.
Regeneration required
Indicator (230/62) flashes slowly
After successful regeneration,
indicator (230/62) goes out again.
114% and
above
Start of the warning levels
Indicator (230/62) flashes quickly.
125% and
above
Indicator (230/58) on.
Reduction of the diesel engine
output
Warning levels are reset
Automatic after successful re-
generation
143 % and
above
Indicator (230/58) flashes.
Additional speed lowering.
Warning levels are reset
Can only be carried out by ser-
vice personnel of the diesel en-
gine manufacturer
214 % and
above
No more regeneration possible.
Replace the diesel particle filter
Measures to be taken when a warning oc-
curs
Perform a regeneration.
If regeneration does not start, shut down
diesel engine as quickly as possible.
Inform diesel engine manufacturer.
I
0
BSB51011
56 62
58
Fig. 230 Diesel particle filter loading
56 Diesel particle filter ash lamp
58 Error display of the engine control system
62 Diesel particle filter regeneration indicator/button
toggle