CARE AND MAINTENANCE 7
MHL360 E 7.15
7.4.2 Fuel system
j WARNING
Burns due to combustible fuels,
lubricants and coolants
The machine must only be refu-
eled when the diesel engine is off.
Smoking is forbidden during refu-
eling. Risk of fire.
In an emergency: Put out the fire,
administer first aid, seek treatment
from a doctor
7.4.2.1 Fuel level
Check the fuel level on the fuel gauge
(254/37). If the fuel in the diesel tank is below
the reserve quantity of 5 %, the indicator
(254/25) lights up and the message (254/34)
"FUEL RESERVE BELOW 5 %" appears on
the multifunction display. To prevent conden-
sation forming before the next time the ma-
chine is put into operation, the tank must be
topped up with fuel daily after use.
ATTENTION
Keep the level of fuel in the tank as high as pos-
sible to prevent condensation from building up.
Never allow the fuel tank to run empty, other-
wise the fuel system will need to be vented.
j
CAUTION
Irritation to skin or eyes due to
diesel fuel spraying out
Wear protective goggles and pro-
tective gloves when filling the
tank.
In an emergency: Wash off diesel
fuel. Administer first aid, seek
treatment from a doctor.
Open the pump (255/1).
Fill the tank.
F
09 :43 11 .03. 2 011
MH LX X X / XXX X
18 00 U PM
0 5 1 0 15 20 2 5
95°C 7 C
0 ½ 1
9 %
120 0
37
25
BSB50607
34
Fig. 254 Fuel level
BSB50006
1
Fig. 255 Fuel tank