7 CARE AND MAINTENANCE
7.76 MHL360 E
7.7.24 Overload warning device (optional)
Danger of injury due to machine
toppling over
• Observe the safety instructions
for the overload warning device in
Chapter 5.
In an emergency: Administer first
aid, seek treatment from a doctor
Function check
► Lift a sufficiently heavy weight and check
whether the warning buzzer and display re-
spond accordingly.
Function check (to be performed by ser-
vice personnel only)
►
Extend the lift cylinder as far as possible.
►
Open the LE diagnostics display screen.
h Chapter 4.5.13.5 LMB/HRB diagnostics
►
Measure the load pressure for the rod end
and base end at the designated measuring
connections, and compare this with the
display. The measured values may deviate
from those on the display by ±5 bar.