Chapter 5: OPERATION
3. GENERAL-PURPOSE BROADCAST
5-26
3.3. Changing the Input Sensitivity and Output Volume Level
By assigning predetermined volume patterns to the Remote Microphone's function keys, the initially set input
sensitivity and output volume level can be changed.
Notes
• Theinputsensitivitycanonlybechangedforsources(suchasthePagingMicrophoneandBGMsource)
connected to the VX-200XI input module or 900 Series modules. Initial volume settings can be performed
for the Remote Microphone and built-in EV and chime units. However, their initial volume levels cannot be
changed during operation.
• TheoutputvolumelevelcanonlybechangedforzoneswhereBGMbroadcastsarebeingmade.Callsfrom
the Remote Microphone or messages of the built-in EV unit are broadcast at the initially set volume level.
• TheinitialoutputvolumelevelcanbesetusingthePCsoftware.
3.3.1. Changing the input sensitivity and output volume level at the Remote Microphone
Both the input sensitivity and output volume level can be changed between
-
21 dB and 0 dB in 3 dB step. They
change by 3 dB each time the corresponding Remote microphone's key is pressed. When the input sensitivity
or output volume level reaches
-
21 dB or 0 dB, further key operation to exceed the limit is ignored.