Chapter 7: PC SOFTWARE OFFLINE SETTINGS
8. SYSTEM SETTING MODE
7-33
8.1.3. General (General-Purpose Broadcast)
Clicking on the [General] button displays all Remote Microphones set for general-purpose broadcast only in the
[RM properties] window, general-purpose EV messages, and sound sources not set for BGM*. All are initially
displayed with the same level of priority.
* When the "Use this source for BGM" checkbox in the 900 module setting window is not ticked, the sound
source broadcast takes precedence over BGM sources. For the VX-2000 input slot settings, refer to
p. 7-21.
Step 1. Select a Remote Microphone, general-purpose message, or sound source, and change its priority by
pressing the Up (
) and Down ( ) buttons.
Step 2. Ifthesameprioritylevelisassignedtomorethanonesoundsource,selecteither[FIFO](rstin,rst
out)or[LIFO](lastin,rstout)prioritysettingsincasesimultaneousbroadcastsaremade.
•FIFO: Priorityisgiventothefirstbroadcastmade.Subsequentbroadcastscannotbemadeuntilthe
first all-zone broadcast is completed.
•LIFO: Priority is given to the most recent broadcast, which overrides any Remote Microphone,
general-purpose message or sound source broadcasts currently in progress .