Chapter 8: INSTALLATION AND SETTING PROCEDURES (HARDWARE)
3. VX-2000SF, VX-200SZ , VX-200SP, VX-200SI , VX-200SO, AND VX-200SE
8-29
3.3 Changing the VX-200SZ's ATT CTRL Output to Photocoupler Type
The ATT CTRL output of the VX-200SZ Impedance Detection Module can be converted from relay to
photocoupler operation. The output is factory-preset for relay operation.
[VX-200SZ]
SJP200
SJP1
SJP1
SJP200
Factory-preset position
Short circuit socket
Step 1. Cut SJP1 with nippers or other cutters.
Step 2. Remove the short circuit socket (SJP200), then
replace it to change its position.