NETS
WORKING WITH NETS
ENVOY™ TRANSCEIVER REFERENCE MANUAL 185
1 Press or to select the value that you want to use from the following:
• If you want all slot widths to match the width required for the largest self
address for a member of the NET, select Fixed.
• If you want the transceiver to calculate the slot width required for the
response from each station, select Variable.
1 If you want to review the information that you have entered, press or to
move through the entries.
1 Press (Save) to save the information.
1 Press (Close).
Changing the order of NET members
Members of a NET have their self address included in the NET Members entry. The
order of these addresses determines the slot in which each station responds to a NET
call. To avoid conflicting responses in a slot, the order of the addresses in the list of
NET members must be identical across all stations that are members of the NET. If
required, you can change the order of the addresses in the list of NET members.
CAUTION: The list of NET members must be the same for all members of the
NET.
To change the order of NET members:
1 From the main menu, select (User Data), then (NETs).
1 Press or to scroll to the NET in which you want to rearrange the NET
members, then press OK.
1 Press to move to the NET Members entry.
1 Press to view the list of NET members.
1 Press or to scroll to the NET member that you want to move.
1 Press (Options), scroll to Move, then press (Select).
1 Press or to scroll to the location to which you want to move the NET
member, then press (Place).
1 Press (Options), scroll to Save, then press (Select).