CDM-625 Advanced Satellite Modem Revision 13
Ethernet-based Remote Product Management MN-CDM625
6–34
Query Interval This is the interval between general queries sent by the modem. By varying
the query interval, a modem administrator may tune the number of IGMP messages on the
subnet; note that larger numbers cause the IGMP queries to be sent less often.
Enter a value, in seconds, from 1 to 18000 (default = 125 seconds)
Query Response Interval This is the maximum response time inserted into the periodic
general queries. By varying the Query Response Interval, a modem administrator may tune
the burstiness” of IGMP messages on the subnet; note that larger values make the traffic
less “bursty” as host responses are spread out over a large interval.
Enter a value, in seconds, from 1 to 25 (default = 10 seconds).
The number of seconds assigned to the Query Response Interval must be less
than the Query Interval.
Click [Submit] to save these settings.
IGMP Joined Groups
This read-only table lists the IGMP Groups that are active on the modem. This allows you to
determine which services are being used and the minimum time before a service will be
terminated.
Click [Refresh] to update this section with its latest available statistics.
Multicast Routes
This read-only table lists the Multicast Routes that are active on the modem.
Click [Refresh] to update this section with its latest available statistics.

Table of Contents