CDM-625 Advanced Satellite Modem Revision 13
Appendix F MN-CDM625
F–45
ODU Selection
If you use ODUs in redundancy, you may toggle this page between the Online and Offline units.
Use the drop-down list to select CSAT #1 or CSAT #2, and then click [Select ODU]. A message in
the right hand column of this section identifies which unit is ‘ONLINE’.
Up Converter Parameters
Frequency Enter a value in MHz.
Attenuation Enter a value in dB.
Slope Mode From the drop-down list, select Manual or Calibrated.
Slope Adjust (Manual Mode Only) Select the desired setting from the drop-down list.
Mute From the drop-down list, select Disable or Enable.
Gain Offset (1:1 Redundancy Only) Select the desired setting from the drop-down list.
Amplifier From the drop-down list, select On or Off.
Down Converter Parameters
Frequency Enter a value in MHz.
Attenuation Enter a value in dB.
Slope Mode From the drop-down list, select Manual or Calibrated.
Slope Adjust (Manual Mode Only) Select the desired setting from the drop-down list.
Mute From the drop-down list, select Disable or Enable.
Gain Offset (1:1 Redundancy Only) Select the desired setting from the drop-down list.
Unit Parameters
Mute Mode From the drop-down list, select Muted after freq change or Unmuted after
freq change.
Auto Fault Recovery, Cold Start, and Ext Reference Fault Logic From the drop-down lists,
select Disable or Enable.
Reference Oscillator AdjustEnter a value from 0-255.