CDM-625 Advanced Satellite Modem Revision 13
DoubleTalk
Carrier-in-Carrier Option MN-CDM625
1022
or during a fade event. This parameter is referred to as TPLI
max
(Transmit Power
Level Increase, max).
If the power changes calculated would put the CnC Ratio out of its working range.
If the Rx signal level is above its minimum level if it is not, the CnC Ratio monitor
will not be accurate, which is essential correct calculations.
If the power change would result in the Eb/No margin on either side becoming
negative (see below).
At the end of the re-balance procedure, the modem will display the result:
Full re-balance.
Partial re-balance.
Some issue was found that prevents a re-balance.
In the case of a partial or no re-balance, the modem displays the reason for this result; you
can then adjust an operating parameter and try again.
IMPORTANT NOTES:
You should be aware that after the re-balance has been carried out, it is
very likely that the CnC Ratio will not be at 0dB, and the Eb/No margins will
not be equal. This is particularly true for cases where there is an asymmetry
in antenna size, terminal G/T, symbol rate etc. This is an inherent function
of the re-balancing algorithm, and is not a cause for concern.
You should only attempt to do a re-balance if it is known with certainty that
there are CLEAR SKY conditions at BOTH SIDES OF THE LINK.
It is not necessary for there to be a person at each end the re-balance can
be initiated from either side, with the other side unattended.
Following the re-balance, the CDM-625 stores key parameters, such as Tx Power level, that
are referred to as the Home State. In the event of a loss of communication between the two
sides, the modem will revert to Home State, which is a known safe condition that will not
cause TCP to be exceeded. Once the link conditions have improved so that communication is
re-established, CnC-APC will automatically re-activate.
2) In the second phase of the algorithm, Eb/No, CnC ratio, and RSL are continuously
monitored. For every combination of the modulation, FEC type and FEC code rate, the
modem calculates an Eb/No margin. An Eb/No margin of 0 dB is arbitrarily determined to
be the Eb/No value that produces a BER of 1 x 10
-7
at the output of the decoder, plus 1 dB.
If the algorithm senses that Eb/No margin is dropping, power is increased at one or both