EasyManua.ls Logo

Datalogic Magellan 9300i - Scanning Features; Double Read Timeout

Datalogic Magellan 9300i
520 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Scanning Features Enter/Exit Programming Mode
Product Reference Guide
127
SCANNING FEATURES
1D Double Read Timeout
The 1D Double Read Timeout feature specifies the minimum allowable time which must
pass before reading the same 1D label again (e.g. two identical items in succession).
To set the Double Read Timeout:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan your selection from the bar codes below. You’ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Programming
Mode bar code.
NOTE
If the incidence of multiple reads is not acceptable, increase the
Double Read Timeout setting to a higher value.
1D Double Read Timeout = 300ms
1D Double Read Timeout = 400ms
1D Double Read Timeout = 600ms
1D Double Read Timeout = 800ms
004D1E(CR)
004D28(CR)
DEFAULT
004D3C(CR)
004D50(CR)

Table of Contents