Enter/Exit Programming Mode 1D Symbology Programming
420 Magellan™ 9300i / 9400i Scanners
Standard 2 of 5 Length 1
If Standard 2 of 5 Length Control is set to Fixed-Length decoding, this feature
specifies Standard 2 of 5 first fixed length. If Standard 2of 5 Length Control is
set to Variable-Length decoding, this feature specifies the minimum label
length.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan the bar code, Set Standard 2 of 5 Length 1 on page 420 below. You’ll
need to cover any unused bar codes on this and the facing page to ensure
that the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the Keypad on page 461 in Appendix C
that represent the desired label length. The selectable range for this
option is 1 to 50. Pad all single digit numbers with a leading zero to yield a
two-digit entry (01-50).
4. Complete the programming sequence by scanning the ENTER/EXIT Pro-
gramming Mode bar code.
Set Standard 2 of 5 Length 1
Default setting for this feature = 08
0498(CR)