Enter/Exit Programming Mode 1D Symbology Programming
406 Magellan™ 9300i / 9400i Scanners
MSI Number of Check Characters
Specifies number of MSI check characters to be calculated and verified.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan the bar code below representing the desired number of MSI check
characters to be calculated and verified. You’ll need to cover any unused
bar codes on this and the facing page to ensure that the scanner reads
only the bar code you intend to scan.
3. Complete the programming sequence by scanning the ENTER/EXIT Pro-
gramming Mode bar code.
NOTE
Check characters are always modulus 10.
MSI Number of Check Characters = 1
MSI Number of Check Characters = 2
DEFAULT
021700(CR)
021701(CR)

Table of Contents

Other manuals for Datalogic Magellan 9300i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 9300i and is the answer not in the manual?

Datalogic Magellan 9300i Specifications

General IconGeneral
Input voltage100 - 240 V
Input frequency50 - 60 Hz
Power source typeAC
Power consumption (standby)11 W
TypeBuilt-in bar code reader
Sensor type-
Scanner type1D/2D
Light levels (direct sunlight)0 - 86080 lx
Linear (1D) barcodes supportedGS1 DataBar Expanded, GS1 DataBar Omnidirectional, JAN, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, Micro QR Code, QR Code
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Standard interfacesRS-232
Connectivity technologyWired
Product colorBlack, Grey
Built-in displayNo
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Weight- g