EAS Beep Duration
Sets the duration of the EAS successful deactivation beep, specified in 10ms
increments. The beep only occurs if EAS mode is not disabled.
To set the EAS Beep Duration:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code, Set EAS Beep Duration on page 191 below. You’ll need
to cover any unused bar codes on this and the facing page to ensure that
the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the Keypad on page 461 in Appendix C
that represent the desired EAS Beep Duration. The selectable range is 0-
255, which is the timeout in 10-millisecond increments. Pad all single and
double digit numbers with leading zeroes to yield a three-digit entry
(000-255).
Examples:
000 = EAS beep disabled
001 = 10ms
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
4. Complete the programming sequence by scanning the nter/Exit Program-
ming Mode bar code.
Set EAS Beep Duration
Default setting for this feature is:
008 - 80ms
0581(CR)