Scanning Features Enter/Exit Programming Mode
Product Reference Guide
143
Illumination Control
This feature allows illumination to be turned off when the scanner is disabled.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan your selection from the bar codes below:
Disable = Illumination remains on during the time the scanner is disabled.
Enable = Illumination turns off during the time the scanner is disabled.
3. Complete the programming sequence by scanning the Enter/Exit Pro-
gramming Mode bar code.
Illumination Control = Disable
Illumination Control = Enable
063A00(CR)
063A01(CR)
DEFAULT

Table of Contents

Other manuals for Datalogic Magellan 9300i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 9300i and is the answer not in the manual?

Datalogic Magellan 9300i Specifications

General IconGeneral
Input voltage100 - 240 V
Input frequency50 - 60 Hz
Power source typeAC
Power consumption (standby)11 W
TypeBuilt-in bar code reader
Sensor type-
Scanner type1D/2D
Light levels (direct sunlight)0 - 86080 lx
Linear (1D) barcodes supportedGS1 DataBar Expanded, GS1 DataBar Omnidirectional, JAN, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, Micro QR Code, QR Code
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Standard interfacesRS-232
Connectivity technologyWired
Product colorBlack, Grey
Built-in displayNo
Sustainability certificatesRoHS
Weight and Dimensions IconWeight and Dimensions
Weight- g