USB Keyboard and Keyboard Wedge Send Control Characters
This feature specifies how the scanner transmits ASCII control characters to the
host.
Choices are:
Disable — No control characters are sent to the host.
Enable transmission of control characters to host — Control characters are sent to
the host.
Send characters between 00H and 1FH — Send characters between 00H and 1FH
according to special function-key mapping table (This is used to send keys that
are not in normal ASCII set; a unique set is provided for each available scancode
set).
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code for the desired setting below. You’ll need to cover any
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the Enter/Exit Pro-
gramming Mode bar code.
NOTE
Affects suffix and prefix characters. When disabled, only ASCII
characters between 20H and 127H inclusive (space... delete)
plus special characters 0DH (carriage return), 08H (backspace),
27H (ESC), 09H (right tab) and 0BH (left tab) are transmitted.
Keyboard Send Control Characters = Disable
Keyboard Send Control Characters =
Enable transmission of control characters to host
USB Keyboard/Keybd Wedge No Keyboard Support =
Send characters between 00H and 1FH
DEFAULT
02C500(CR)
02C501(CR)
02C502(CR)

Table of Contents

Other manuals for Datalogic Magellan 9300i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 9300i and is the answer not in the manual?

Datalogic Magellan 9300i Specifications

General IconGeneral
Input voltage100 - 240 V
Input frequency50 - 60 Hz
Power source typeAC
Power consumption (standby)11 W
TypeBuilt-in bar code reader
Sensor type-
Scanner type1D/2D
Light levels (direct sunlight)0 - 86080 lx
Linear (1D) barcodes supportedGS1 DataBar Expanded, GS1 DataBar Omnidirectional, JAN, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, Micro QR Code, QR Code
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Standard interfacesRS-232
Connectivity technologyWired
Product colorBlack, Grey
Built-in displayNo
Sustainability certificatesRoHS